04407A1 | Hydrogen Purity Analyser Base |
includes report software, SS liners, packaging | |
Trace (>10 ppm), Pack 1 | N2 Impurity - Enter range & LDL |
0-10ppm ≤N2 range ≤ 0-200ppm LDL is 1.5% full scale | |
(with O2 trap in aux oven) | |
Trace (>10 ppm), Pack 2 | Same as Pack 1 + |
CO2 Impurity - Enter range & LDL | |
0-10ppm ≤CO2 range ≤ 0-200ppm LDL is 1.5% full scale | |
CH4 Impurity - Enter range & LDL | |
0-10ppm ≤CH4 range ≤ 0-200ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 3 | CO Impurity - Enter range & LDL |
0-10ppm ≤CO range ≤ 0-200ppm LDL is 1.5% full scale | |
CO2 Impurity - Enter range & LDL | |
0-10ppm ≤CO2 range ≤ 0-200ppm LDL is 1.5% full scale | |
CH4 Impurity - Enter range & LDL | |
0-10ppm ≤CH4 range ≤ 0-200ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 4 | Same as Pack 2 + |
CO Impurity - Enter range & LDL | |
0-10ppm ≤CO range ≤ 0-200ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 5 | Same as Pack 4 + |
Ar Impurity - Enter range & LDL | |
0-10ppm ≤Ar range ≤ 0-200ppm LDL is 1.5% full scale | |
Trace Exact (<10 ppm), Pack 1 | N2 Impurity - Enter range & LDL (with O2 trap in aux oven) |
0-1ppm ≤N2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Min Range 0-1 ppm | CO2 Impurity - Enter range & LDL |
0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
CH4 Impurity - Enter range & LDL | |
0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Trace Exact (<10 ppm), Pack 2 | CO Impurity - Enter range & LDL |
0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Min Range 0-1 ppm | CO2 Impurity - Enter range & LDL |
0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
CH4 Impurity - Enter range & LDL | |
0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Trace Exact (<10 ppm), Pack 2 | Same as Pack 1 + |
CO Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Carrier Gas | Argon |
Helium (if Argon impurity) | |
Power | 115 VAC, 50-60 Hz |
220 VAC, 50-60 Hz | |
Gas Connectors (to match accessories fittings) | 1/8" Swagelok |
1/8" VCR (if 0-1 ppm range) | |
Serial port | Not Required |
RS-232 | |
Remote Support | VNC |
Net Support | |
Dual Inlets (sample + span, with switching) | Not Required |
Required | |
Calibration using background gas | Not required |
Required | |
04408A1 | Carbon Dioxide Purity Analyser Base |
includes report software, SS liners, packaging | |
Trace (>10 ppm), Pack 1 | O2 Impurity - Enter range & LDL |
0-10ppm ≤O2 range ≤ 0-100ppm LDL is 1.5% full scale | |
H2 Impurity - Enter range & LDL | |
0-10ppm ≤H2 range ≤ 0-100ppm LDL is 1.5% full scale | |
N2 Impurity - Enter range & LDL | |
0-10ppm ≤N2 range ≤ 0-100ppm LDL is 1.5% full scale | |
CH4 Impurity - Enter range & LDL | |
0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 2 | Same as Pack 1 + |
CO Impurity - Enter range & LDL | |
0-10ppm ≤CO range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 3 | Same as Pack 2 + |
Ar Impurity - Enter range & LDL | |
0-10ppm ≤Ar range ≤ 0-100ppm LDL is 1.5% full scale | |
Carrier Gas | Argon |
Helium (if Argon impurity) | |
Power | 115 VAC, 50-60 Hz |
220 VAC, 50-60 Hz | |
Gas Connectors (to match accessories fittings) | 1/8" Swagelok |
1/8" VCR (if 0-1 ppm range) | |
Serial port | Not Required |
RS-232 | |
Remote Support | VNC |
Net Support | |
Dual Inlets (sample + span, with switching) | Not Required |
Required | |
Calibration using background gas | Not required |
Required | |
SERVOFLEX 5200 MULTI PURPOSE ANALYSER | |
05230A1 | 5200 Multi Purpose |
SUPPLY POWER | UK Mains |
European Mains | |
US Mains | |
Japanese Mains (no plug fitted) | |
Rechargeable Lithium ion battery (UK) | |
Rechargeable Lithium ion battery (US) | |
Rechargeable Lithium ion battery (Euro) | |
Rechargeable Lithium ion battery (Japan) | |
MEASUREMENT 1 | Oxygen, standard accuracy (1116) |
Oxygen, industrial version (3601, 1 dec place) | |
Oxygen, high accuracy (3601, 2 dec place) | |
0-10% Carbon Dioxide | |
0-25% Carbon Dioxide | |
0-50% Carbon Dioxide | |
0-100% Carbon Dioxide | |
MEASUREMENT 2 | 0-10% Carbon Dioxide |
0-25% Carbon Dioxide | |
0-50% Carbon Dioxide | |
0-100% Carbon Dioxide | |
SAMPLING | Automatic Flow Control Device |
Internal Pump | |
mA OUTPUTS | mA outputs, one transducer fitted |
mA outputs, two transducers fitted | |
CONNECTORS | Quickconnect 1/4" barb fitting |
Barb as above plus adaptor to 1/8" NPT | |
EXHAUST / VENT OUTLETQ | Rear Panel |
Front Panel | |
VEHICLE ADAPTOR | 12/24V Vehicle Power Adaptor |
PRINTER* | Thermal Printer Kit (Universal) |
SIDE PANEL ACCESSORIES | Sample Conditioning Panel (not for O2 std transducer) |
Choose only one | Flow Meter + Valve (not for AFCD version) |
Flow Meter (analyser with AFCD) | |
PROBE HOLDER | Supplied (for SCP only) |
Supplied including Filter (not for SCP) | |
SAMPLE PROBE | Not Supplied |
25cm, SS, Tip, <180C | |
1m SS | |
TRANSPORT CASE | None |
Protective plastic transport case, std pre-cut foam | |
USER MANUAL | English |
French | |
German | |
Italian | |
ACCESSORIES | |
202517 | Additional barbed Quickconnect fitting |
(1 supplied as standard. Some users may wish | |
to purchase additional fittings for zero and span | |
gas to speed connections during calibration) | |
5200991 | Additional Quickconnect adaptor to 1/8" NPT |
203022 | Additional rolls of printer paper (pack of 5) |
570982 | Replacement filters (pack of 5) |
NOTE: 3 filters supplied with analyser | |
2323-7029 | Replacement Viton O-ring for AFCD |
5200992 | Carry Case with foam inserts |
Note: If printer ordered as loose item after initial purchase price is higher | |
209961 | Thermal Printer Kit (Universal)*** |
*This price only when purchased with analyser. Includes 1 roll of paper. | |
***The instrument will only print properly to the printer supplied by Servomex. | |
SERVOFLEX 5200 FOOD PACK ANALYSER | |