04416A1 | SERVOPRO NanoChrome He Background |
includes report software, packaging | |
Impurities options | |
N2 Range 0-250ppb LDL 0.3ppb | INJ with 1 valves |
Ar Range 0-250ppb LDL 0.5ppb | INJ/HC with 2 valves |
H2 Range 0-250ppb LDL 0.5ppb | INJ with 1 valves |
N2/H2 Range 0-250ppb LDL 0.5ppb | INJ with 1 valves |
CO Range 0-250ppb LDL 0.5ppb | INJ with 1 valves |
CO2 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
CO2/CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb | BF/HC/SEL with 3 valves |
Chassis options | |
Master Chassis | Max. 2 channels with 4 valves |
PC+ Slave chassis | 2 BF/HC channels |
Master +Slave1 Chassis | Max. 4 channels with 8 valves |
Carrier Gas | Helium |
Power | 115 VAC, 50-60 Hz |
220 VAC, 50-60 Hz | |
Gas Connectors (to match accessories fittings) | 1/8" VCR |
Serial port | RS-232 |
Remote Support | VNC |
Net Support | |
Internal Dilution System | Not Required ( > 1ppm) |
Required ( One per Chassis) | |
SERVOPRO PureGas | Gas Purifier |
02005A1_01 | SERVOPRO PUREGAS, 1/8" COMP, 110V |
02005A1_02 | SERVOPRO PUREGAS, 1/8" COMP, 220V EU |
02005A1_03 | SERVOPRO PUREGAS, 1/8" COMP, 220V UK |
02005A1_04 | SERVOPRO PUREGAS, 1/8" VCR, 110V |
02005A1_05 | SERVOPRO PUREGAS, 1/8" VCR, 220V EU |
02005A1_06 | SERVOPRO PUREGAS, 1/8" VCR, 220V UK |
SpectraScan Analyser | |
02400A1 | SpectraScan Analyser |
Components | 1 to 3 Components |
4 to 6 Components | |
7 to 8 Components | |
04404A1 | Nitrogen Purity Analyser Base |
includes report software, SS liners, packaging | |
Trace (>10 ppm), Pack 1 | O2 Impurity - Enter range & LDL |
0-10ppm ≤O2 range ≤ 0-100ppm LDL is 1.5% full scale | |
H2 Impurity - Enter range & LDL | |
0-10ppm ≤H2 range ≤ 0-100ppm LDL is 1.5% full scale | |
CH4 Impurity - Enter range & LDL | |
0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 2 | Same as Pack 1 + |
Ar Impurity - Enter range & LDL | |
0-10ppm ≤Ar range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 3 | Same as Pack 2 + |
CO Impurity - Enter range & LDL | |
0-10ppm ≤CO range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 4 | Same as Pack 3 + |
CO2 Impurity - Enter range & LDL | |
0-10ppm ≤CO2 range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace Exact (<10 ppm), Pack 1 | O2 Impurity - Enter range & LDL |
0-1ppm ≤O2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Min Range 0-1 ppm | H2 Impurity - Enter range & LDL |
0-1ppm ≤H2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
CH4 Impurity - Enter range & LDL | |
0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Trace Exact (<10 ppm), Pack 2 | Same as Pack 1 + |
Ar Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤Ar range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Trace Exact (<10 ppm), Pack 3 | Same as Pack 2 + |
CO Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Trace Exact (<10 ppm), Pack 4 | Same as Pack 3 + |
CO2 Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Carrier Gas | Argon |
Helium (if Argon impurity) | |
Power | 115 VAC, 50-60 Hz |
220 VAC, 50-60 Hz | |
Gas Connectors (to match accessories fittings) | 1/8" Swagelok |
1/8" VCR (if 0-1 ppm range) | |
Serial port | Not Required |
RS-232 | |
Remote Support | VNC |
Net Support | |
Dual Inlets (sample + span, with switching) | Not Required |
Required | |
Calibration using background gas | Not required |
Required | |
04405A1 | Oxygen Purity Analyser Base |
includes report software, SS liners, packaging | |
ASU Process (>10 ppm), Pack 1 | CH4 Impurity - Enter range & LDL |
0-10ppm ≤CH4 range ≤ 0-500ppm LDL is 1.5% full scale | |
NMHC Impurity - Enter range & LDL | |
0-5ppm ≤CH4 range ≤ 0-200ppm LDL is 1.5% full scale Min.100ppb | |
Trace (>10 ppm), Pack 1 | N2 Impurity - Enter range & LDL |
0-10ppm ≤N2 range ≤ 0-100ppm LDL is 1.5% full scale | |
(with O2 trap in aux oven) | |
Trace (>10 ppm), Pack 2 | Same as Pack 1 + |
H2 Impurity - Enter range & LDL | |
0-10ppm ≤H2 range ≤ 0-100ppm LDL is 1.5% full scale | |
CH4 Impurity - Enter range & LDL | |
0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 3 | Same as Pack 2 + |
CO2 Impurity - Enter range & LDL | |
0-10ppm ≤CO2 range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 4 | Same as Pack 3 + |
CO Impurity - Enter range & LDL | |
0-10ppm ≤CO range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace (>10 ppm), Pack 5 | Same as Pack 4 + |
Ar Impurity - Enter range & LDL | |
0-10ppm ≤Ar range ≤ 0-100ppm LDL is 1.5% full scale | |
Trace Exact (<10 ppm), Pack 1 | N2 Impurity - Enter range & LDL |
0-1ppm ≤N2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Min Range 0-1 ppm | (with O2 trap in aux oven) |
Trace Exact (<10 ppm), Pack 2 | Same as Pack 1 + |
Min Range 0-1 ppm | H2 Impurity - Enter range & LDL |
0-1ppm ≤H2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
CH4 Impurity - Enter range & LDL | |
0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb | |
Trace Exact (<10 ppm), Pack 3 | Same as Pack 2 + |
CO2 Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Trace Exact (<10 ppm), Pack 4 | Same as Pack 3 + |
CO Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Trace Exact (<10 ppm), Pack 5 | Same as Pack 4 + |
Ar Impurity - Enter range & LDL | |
Min Range 0-1 ppm | 0-1ppm ≤Ar range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
Carrier Gas | Argon |
Helium (if Argon impurity measured) | |
Power | 115 VAC, 50-60 Hz |
220 VAC, 50-60 Hz | |
Gas Connectors (to match accessories fittings) | 1/8" Swagelok |
1/8" VCR (if 0-1 ppm range) | |
Serial port | Not Required |
RS-232 | |
Remote Support | VNC |
Net Support | |
Dual Inlets (sample + span, with switching) | Not Required |
Required | |
Calibration using background gas | Not required |
Required | |