CellaTemp PQ/PL Series

The CellaTemp PQ/PL compact pyrometers feature an integrated LED display. The temperature reading can be viewed even at a distance of several meters. Connect a USB interface to set parameters such as emissivity and smoothing function or to perform diagnostics from a PC. CellaTemp PQ models 27, 28 and 38 provide a patented LED spot light as a target marker. All CellaTemp PL models feature this LED spot light as well as focusable lenses. The LED spot light facilitates sharp focussing and indicates the exact size and position of the measured target spot.

Device Temperature Application Wavelength Focusing distance
PQ 11 0 - 1000 °C plastics
rubber
paper
ceramics
textiles
foodstuffs
liquids
paints and varnishes
asphalt
wood
glass
coated metals
8 – 14 µm 300 mm
PQ 12 -30 - 300 °C identical to PQ 11 8 – 14 µm 300 mm
PQ 13 0 - 1000 °C identical to PQ 11 8 - 14 µm 1000 mm
PQ 14 0 - 300 °C identical to PQ 11 8 – 14 µm 1000 mm
PQ 15 0 - 1000 °C identical to PQ 11 8 – 14 µm 300 mm
PQ 16 0 - 1000 °C identical to PQ 11 8 – 14 µm 100 mm
PQ 21 250 - 1600 °C metals
molten glass
graphite
ceramics
annealing
forging
sintering
heat treatment
rolling mill
1.0 - 1.7 µm 800 mm
PQ 22 250 - 1600 °C identical to PQ 21 1.0 - 1.7 µm 1000 mm
PQ 23 250 - 1600 °C identical to PQ 21 1.0 - 1.7 µm 300 mm
PQ 24 250 - 1600 °C identical to PQ 21 1.0 - 1.7 µm 300 mm
PQ 26 300 - 2000 °C metals
molten glass
graphite
ceramics
annealing
forging
sintering
heat treatment
rolling mill
1.0 - 1.7 µm variable
PQ 27 250 - 1600 °C laser applications
diode lasers
1.2 - 1.7 µm 200 mm
PQ 28 250 - 1600 °C metals
brazing
sintering
induction heating
billet heating
1.1 - 1.7 µm 200 mm
PQ 29 150 - 800 °C metals
aluminium
1.8 - 2.2 µm 300 mm
PQ 31 500 - 2500 °C identical to PQ 21 0.78 - 1.06 µm 800 mm
PQ 32 500 - 2500 °C identical to PQ 21 0.78 - 1.06 µm 1000 mm
PQ 36 550 - 2500 °C identical to PQ 26 0.78 - 1.06 µm variable
PQ 38 500 - 2500 °C metals
brazing
sintering
induction heating
billet heating
0.78 - 1.06 µm 200 mm
PQ 41 300 - 1300 °C glass surfaces 4.6 - 4.9 µm 400 mm
PQ 42 700 - 2500 °C glass surfaces 4.6 - 4.9 µm 400 mm
PQ 51 400 - 1400 °C flame-heated furnaces 3.8 - 4.0 µm 400 mm
PL 11 0 -1000 °C identical to PQ 11 8 - 14 µm variable
PL 21 250 - 1600 °C identical to PQ 21, PQ 28 1.0 - 1.7 µm variable
PL 22 250 - 1600 °C identical to PL 21 1.0 - 1.7 µm variable
PL 31 500 - 2500 °C identical to PL 21 0.78 - 1.06 µm variable
PL 32 500 - 2500 °C identical to PL 21 0.78 - 1.06 µm variable

 