SERVOTOUGH LaserSP Mini | |
07930A1 | |
Talking PN Reference | |
Analyser Reference | 07931A1- |
Mounting Reference | 07931M- |
Accessories Reference | 07931AA- |
ANALYSER CONFIGURATION | |
Analyser Type | SP Mini |
Measurement 1 | A - Oxygen Low Temperature (<500 C) |
F - Ammonia | |
Measurement 1, Range | |
B 0-15 ppm | |
C 0-25 ppm | |
D 0-50 ppm | |
E 0-100 ppm | |
F 0-200 ppm | |
G 0-250 ppm | |
H 0-500 ppm | |
J 0-1000 ppm | |
K 0-2500 ppm | |
L 0-5000 ppm | |
R 0-1% | |
S 0-5% | |
T 0-10% | |
U 0-21% | |
V 0-25% | |
Area Classification | Safe Area / General Purpose |
ATEX GAS Category 3G / IECEx Zone 2 | |
CSA Class 1 Division 2 | |
ATEX DUST Only Category 2D / IECEx Zone 21 | |
Total Path Length | < 2m (standard colimated Beam) |
2m to 12 m (standard optics - Beam Divergence 0.8) | |
> 12m (long pathlength optics - Beam Divergence 0.6) | |
Additional Inputs/Outputs | None (standard 1 x 4-20 mA output, 1 x relays) |
Required (additional 1 x mA output, 2 x 4-20 mA input, 2 x relays) | |
Process Pressure / Temperature | <= 1.5barA & <=500°C |
>1.5barA to 16barA & <=500°C | |
MOUNTING CONFIGURATION | |
Isolation Flange | None |
Customer Supplied | |
DN50 | |
2" ANSI | |
Tx Mounting Type | Fixed |
Premium - Ball Joint | |
Tx Flange Size | DN25 |
DN50 | |
1" ANSI | |
2" ANSI | |
3" ANSI | |
Rx Mounting Type | Fixed |
Premium - Ball Joint | |
Rx Flange Size | DN25 |
DN50 | |
1" ANSI | |
2" ANSI | |
3" ANSI | |
Seal Material (Sample Wetted) | Fluorocarbon (Viton 70) |
Chemraz (Chemraz 505) | |
Insertion Tubes | None |
2" ANSI 316SS Narrow Bore | |
2" ANSI 316SS Standard Bore | |
DN50 316SS Standard Bore | |
2"ANSI Combo I F / 316SS S B | |
Thermal Break | None |
DN25 | |
DN50 | |
1" ANSI | |
2" ANSI | |
3" ANSI | |
In Line Span Cell | None |
Required | |
Accessories CONFIGURATION | |
Analyser Purge | |
Window Purge | None |
Instrument Air | |
Nitrogen | |
Measurement Purge | Blanked |
Instrument Air | |
Nitrogen | |
Environmental Purge | None |
Instrument Air | |
Nitrogen | |
Purge Fitting Type | None (1/8" NPT F) |
Metric (6mm Compression Fittings) | |
Imperial (1/4" Compression Fittings) | |
Purge Panel | None |
Option 1 - Window Purge Only | |
Option 2 - Window Purge plus Cal Cell | |
Option 3 - Window and case Purge | |
Option 4 - Window and case Purge plus Cal Cell | |
Option 5 - Purge Windows, Case, Laser and Detector | |
Option 6 - Purge Windows, Case, Laser and Detector plus cal cell | |
Power supply | 24 V dc |
100-240 V / 50-60 Hz External Transformer | |
Manuals: User / Installation / Safety | English |
Manuals: Service | None |
English | |
Alignment Tool | None |
Calibration Cell Kit | None |
250 mm | |
500 mm | |
750 mm | |
1000 mm | |
InterConnection Cable | None |
Servomex Standard | |
Interconnection Cable length | |
Interconnection cable / M | |
SERVOPRO MULTIEXACT GAS PURITY ANALYSER | |
05410A1 | |
Base Analyser | |
Supply | |
UK Power Lead | |
European Power Lead | |
American Power Lead | |
Gas Module 1 | |
O2 Purity | |
O2 Control | |
O2 Trace | |
0-10 ppm CO2 Trace | |
0-500 ppm CO2 Trace | |
0-20 ppmN2O Trace | |
0-10 ppm CO Trace | |
Thermal Conductivity - Ar | |
Thermal Conductivity - N2 | |
Thermal Conductivity - He | |
Sample System Module 1 | |
Flow Driven Paramagnetic | |
Flow Driven Zirconia | |
Flow Driven Gfx | |
Pressure Driven Paramagnetic | |
Pressure Driven Zirconia | |
Pressure Driven Gfx | |
Fascia Options Module 1 | |
Blank | |
Sample Flowmeter | |
Bypass Flowmeter | |
Sample + Bypass Flowmeter | |
Filter (Pm only) | |
Filter (Pm only) + Sample Flowmeter | |
Filter (Pm only) + Bypass Flowmeter | |
Gas Module 2 | |
O2 Purity | |
O2 Control | |
O2 Trace | |
0-10 ppm CO2 Trace | |
0-500 ppm CO2 Trace | |
0-20 ppmN2O Trace | |
0-10 ppm CO Trace | |
Thermal Conductivity - Ar | |
Thermal Conductivity - N2 | |
Thermal Conductivity - He | |
Sample System Module 2 | |
Flow Driven Paramagnetic | |
Flow Driven Zirconia | |
Flow Driven Gfx | |
Pressure Driven Paramagnetic | |
Pressure Driven Zirconia | |
Pressure Driven Gfx | |
Fascia Options Module 2 | |
Blank | |
Sample Flowmeter | |
Bypass Flowmeter | |
Sample + Bypass Flowmeter | |
Filter (Pm only) | |
Filter (Pm only) + Sample Flowmeter | |
Filter (Pm only) + Bypass Flowmeter | |
External Filter Module 1 | |
Not Supplied | |
Particulate Filter (not Zirconia) | |
External Filter Module 2 | |
Not Supplied | |
Particulate Filter (not Zirconia) | |
Flow Alarm | |
Flow Alarm Module 1 | Not required |
Flow Alarm | |
Flow Alarm Module 2 | Not required |
Flow Alarm | |
Analogue Outputs | |
Gas Module 1 | mA Analogue Output |
Voltage Analogue Output | |
Gas Modules 1 & 2 | mA Analogue Output |
Voltage Analogue Output | |
Valve Block | (requires AutoVal/Cal relays) |
Not required | |
Gas Module 1 | Required |
Not required | |
Gas Modules 1 and 2 | Required |
AutoVal / Cal relays | |
Not required | |
Gas Module 1 | AutoVal / Cal required |
Not required | |
Gas Modules 1 & 2 | AutoVal / Cal required |
Alarm / Status Relays | |
Not required | |
Gas Module 1 | Relay required |
Not required | |
Gas Modules 1 & 2 | Relay required |
Digital Communications | |
ModBus RS485 | |
ModBus TCP (Ethernet) | |
ProfiBus | |
Mounting | |
Bench | |
19" Rack Mount Ears Only | |
19" Rack Slide Mount | |
Operators Manual | |
English | |
French | |
German | |
Back Pressure Valve (External) | |
Required | |
SERVOPRO MonoExact TCD GAS ANALYSER | |
05512A1 Base Analyser | |
GAS MODULE CONFIGURATION | |
Gas Module | Thermal Conductivity |
Sample/Background Gas | Ar in N2/O2/Air |
N2 in Ar | |
He in N2 | |
He in O2 | |
Range | 0 -2% Only available for "He in N2" or "He in O2" |
(Check VC for permitted ranges) | 0 - 5% Only available for "He in N2" or "He in O2" |
0 - 10% | |
0 - 20% | |
0 - 30% Only available for "He in N2" or "He in O2" | |
0 - 50% Not available for "N2 in Ar" | |
0 - 100% Not available for "N2 in Ar" | |
80 - 100% Not available for "N2 in Ar" | |
90 - 100% Not available for "N2 in Ar" | |
Sample System | Flow Driven |
Pressure Driven | |
Fascia Options | Blank |
Sample Flowmeter | |
Filter | |
GENERAL CONFIGURATION | . |
Power Supply | UK Power Lead |
European Power Lead | |
American Power Lead | |
Analogue Output | mA Output |
Voltage Output (0-10V) | |
Digital Output | Not Required |
ModBus RS485 | |
ModBus TCP (Ethernet) | |
Profibus | |
Relay Option Card | Not Required |
Alarms & Status | |
Auto Val / Cal | |
Mounting Option | Bench |
Panel | |
Rack | |
User Manual | English |
English (Russian MultiExact HW) | |