optical-scale-gms-v-thang-do-quang-givimisure-vietnam-stc-vietnam.png

MECHANICAL

 

ELECTRICAL

SIGNALS

CONDUCTOR COLOR

A

Green

A

Brown

B

Black

B

Red

I0

Grey

I0

Pink

Not connected

Violet

V- sense

Blue

V+ sense

White

V-

Green - White

V+

Green - Yellow

SHIELD

Shield

 

Cod. GMS

V40

Measuring support

 

Grating pitch

 

Thermal expansion coefficient

stainless steel

 

40  m                   P

10.6 x 10-6 °C-1

 

Reference index (I0)

C= coded distance (80 mm) P= constant step (50 mm) E= selectable (with magnet)

Resolution

up to 0.1  m *

Accuracy grade

± 10  m **

 

Measuring length ML in mm

up to 30040 mm with steps of 200 mm

Segments length: 1000, 1200, 1400, 1600, 1800,

2000 mm

Max. traversing speed

60 m/min

Max. acceleration

30 m/s2

Required moving force

£ 6 N  (0.6 Kgf)

Vibration resistance (EN 60068-2-6)

£ 100 m/s2       [50 ¸ 2000 Hz]

Shock resistance (EN 60068-2-27)

£ 300 m/s2       [11 ms]

Protection class (EN 60529)

IP 53 standard         IP 64 pressurized

Operating temperature

0 ¸ 50 °C

Storage temperature

-20 ¸ 70 °C

Relative humidity

20% ¸ 70% (not condensed)

Sliding block

by ball bearings   

Power supply

5 V ± 5%

Current consumption

100 mAMAX (with R = 120 W)

A and B output signals Period

1 Vpp

40  m

Maximum cable length

150 m

Electrical connections

see related table

Connector

in the transducer

Electrical protections

inversion of polarity and short circuits

Weight