| 05522A1 Base Analyser (stainless steel pipework, flam | able gases) |
| GAS MODULE CONFIGURATION | |
| Gas Module | Thermal Conductivity |
| Sample/Background Gas | H2 in Ar |
| H2 in N2 | |
| H2 in CO | |
| Range | 0 - 1% Not available for "H2 in Ar" |
| (Check VC for permitted ranges) | 0 - 2% Only available for "H2 in N2" |
| 0 - 5% Only available for "H2 in N2" | |
| 0 - 10% Only available for "H2 in N2" | |
| 0 - 20% Not available for "H2 in CO" | |
| 0 - 50% Only available for "H2 in N2" | |
| 0 - 100% Only available for "H2 in N2" | |
| 90 - 100% Only available for "H2 in N2" | |
| Sample System | Flow Driven |
| Fascia Options | Blank |
| GENERAL CONFIGURATION | . |
| Power Supply | UK Power Lead |
| European Power Lead | |
| American Power Lead | |
| Analogue Output | mA Output |
| Voltage Output (0-10V) | |
| Digital Output | Not Required |
| ModBus RS485 | |
| ModBus TCP (Ethernet) | |
| Profibus | |
| Relay Option Card | Not Required |
| Alarms & Status | |
| Auto Val / Cal | |
| Mounting Option | Bench |
| Panel | |
| Rack | |
| User Manual | English |
| English (Russian MultiExact HW) | |
| SERVOPRO 4100 GAS PURITY ANALYSER | |
| 04100C1 | |
| CHASSIS TYPE | |
| Short Chassis (max 2 short or 1 long sensor modules) | |
| Long Chassis (max 4 short or 2 long sensor modules) | |
| Extended chassis (max 2 long sensor modules) | |
| GAS SENSOR MODULE 1 | |
| Short Sensor Modules | |
| PM O2 Purity | |
| PM O2 Control | |
| PM O2 Basic | |
| Zr O2 703 Trace | |
| Zr O2 704 Trace | |
| 1520 IR, 100% CO2 | |
| 1520 IR, 50% CO2 | |
| 1520 IR, 25% CO2 | |
| 1520 IR, 10% CO2 | |
| 1520 IR, 5% CO2 | |
| 1520 IR, 2.5% CO2 | |
| 1520 IR, 1% CO2 | |
| 1522 IR, 10% CO | |
| Long Sensor Modules | |
| 1520 IR, 5000vpm CO2 | |
| 1520 IR, 2500vpm CO2 | |
| 1522 IR, 2.5% CO | |
| 1522 IR, 1% CO | |
| GFX CO 0-10/50vpm | |
| GFX CO 0-10/50vpm (background O2) | |
| GFX CO 0-50/500vpm | |
| GFX CO2 0-5/100vpm | |
| GFX CO2 0-50/500vpm | |
| GFX CO2 0-50/500vpm (background O2) | |
| GFX N2O 0-50/500vpm | |
| GFX N2O 0-50/500vpm (background O2) | |
| GFX CH4 0-50/500vpm | |
| **Simplified SIPS GFX CO 0-100/1000vpm** | |
| **Simplified SIPS GFX CO 0-500/5000vpm** | |
| **Simplified SIPS GFX CH4 0-100/1000vpm** | |
| GAS SENSOR MODULE 3 | |
| None | |
| Short Sensor Modules | |
| PM O2 Purity | |
| PM O2 Control | |
| PM O2 Basic | |
| Zr O2 703 Trace | |
| Zr O2 704 Trace | |
| 1520 IR, 100% CO2 | |
| 1520 IR, 50% CO2 | |
| 1520 IR, 25% CO2 | |
| 1520 IR, 10% CO2 | |
| 1520 IR, 5% CO2 | |
| 1520 IR, 2.5% CO2 | |
| 1520 IR, 1% CO2 | |
| 1522 IR, 10% CO | |
| Long Sensor Modules | |
| 1520 IR, 5000vpm CO2 | |
| 1520 IR, 2500vpm CO2 | |
| 1522 IR, 2.5% CO | |
| 1522 IR, 1% CO | |
| GFX CO 0-10/50vpm | |
| GFX CO 0-10/50vpm (background O2) | |
| GFX CO 0-50/500vpm | |
| GFX CO2 0-5/100vpm | |
| GFX CO2 0-50/500vpm | |
| GFX CO2 0-50/500vpm (background O2) | |
| GFX N2O 0-50/500vpm | |
| GFX N2O 0-50/500vpm (background O2) | |
| GFX CH4 0-50/500vpm | |
| **Simplified SIPS GFX CO 0-100/1000vpm** | |
| **Simplified SIPS GFX CO 0-500/5000vpm** | |
| **Simplified SIPS GFX CH4 0-100/1000vpm** | |
| SAMPLE SYSTEM FOR MODULE 1 | |
| Flow Driven PM | |
| Flow Driven Zr | |
| Flow Driven 152x series | |
| Flow Driven GFX | |
| Flow Driven GFX with flow alarm | |
| Pressure Driven PM | |
| Pressure Driven PM Basic | |
| Pressure Driven Zr | |
| Pressure Driven 152x series | |
| Pressure Driven GFX | |
| SAMPLE SYSTEM FOR MODULE 3 | |
| None | |
| Flow Driven PM | |
| Flow Driven Zr | |
| Flow Driven 152x series | |
| Flow Driven GFX | |
| Flow Driven GFX with flow alarm | |
| Pressure Driven PM | |
| Pressure Driven PM Basic | |
| Pressure Driven Zr | |
| Pressure Driven 152x series | |
| Pressure Driven GFX | |
| GAS SENSOR MODULE 2 | |
| Only available if a short sensor was selected for Module 1 | |
| None | |
| Short Sensor Modules | |
| PM O2 Purity | |
| PM O2 Control | |
| PM O2 Basic | |
| Zr O2 703 Trace | |
| Zr O2 704 Trace | |
| 1520 IR, 100% CO2 | |
| 1520 IR, 50% CO2 | |
| 1520 IR, 25% CO2 | |
| 1520 IR, 10% CO2 | |
| 1520 IR, 5% CO2 | |
| 1520 IR, 2.5% CO2 | |
| 1520 IR, 1% CO2 | |
| 1522 IR, 10% CO | |
| SAMPLE SYSTEM FOR MODULE 2 | |
| None | |
| Flow Driven PM | |
| Flow Driven Zr | |
| Flow Driven 152x series | |
| Pressure Driven PM | |
| Pressure Driven PM Basic | |
| Pressure Driven Zr | |
| Pressure Driven 152x series | |
| GAS SENSOR MODULE 4 | |
| Only available if a short sensor was selected for Module 3 | |
| None | |
| Short Sensor Modules | |
| PM O2 Purity | |
| PM O2 Control | |
| PM O2 Basic | |
| Zr O2 703 Trace | |
| Zr O2 704 Trace | |
| 1520 IR, 100% CO2 | |
| 1520 IR, 50% CO2 | |
| 1520 IR, 25% CO2 | |
| 1520 IR, 10% CO2 | |
| 1520 IR, 5% CO2 | |
| 1520 IR, 2.5% CO2 | |
| 1520 IR, 1% CO2 | |
| 1522 IR, 10% CO | |
| Long Sensor Modules | |
| Only available with extended chassis | |
| GFX CO 0-10/50vpm | |
| GFX CO 0-10/50vpm (background O2) | |
| GFX CO2 0-50/500vpm | |
| GFX CO2 0-50/500vpm (background O2) | |
| SAMPLE SYSTEM FOR MODULE 4 | |
| None | |
| Flow Driven PM | |
| Flow Driven Zr | |
| Flow Driven 152x series | |
| Flow Driven GFX (extended chassis only) | |
| Pressure Driven PM | |
| Pressure Driven PM Basic | |
| Pressure Driven Zr | |
| Pressure Driven 152x series | |
| Pressure Driven GFX (extended chassis only) | |
| SPR410 (BPV) | |
| Purity Module 1 | |
| Purity Module 2 | |
| Purity Module 3 | |
| Purity Module 4 | |
| FLOWMETER (LEFT) | |